Continuing from Part 1. This round is the access-control layer itself and where it all lands.

Door hardware — a “Push to Exit” REX button set into the wall by each secured door, and standard mechanical deadbolts kept in place as a fallback (UniFi Access controls the electric strike, the physical lock is still there if the network layer goes down).

REX button and conduit at the door frame deadbolt, lever and REX on a secured door REX button close-up

Head-end lives in a ceiling utility space, not a server room — a small wall-mounted rack cabinet holds the switch and a UDM-class controller, an AP is Ethernet-fed off the same drop, and a NAS sits alongside for local video/log retention. Ran conduit for the low-voltage runs rather than open cable, which cost more time up front and saved a lot of hassle troubleshooting later.

head-end rack

Lessons so far: plan your reader mounting height and REX placement before drywall goes back up, not after — one of ours needed a second cut. UDM-class gear in a ceiling space needs real thought about heat; ours has passive venting and we’re watching temps over the first month.